Release Notes WITE32 Version 3.11 6/28/2004 Copyright 2004 Guzik Technical Enterprises. All rights reserved
WITE32 Release Notes Version 3.11 The new Erase Setup button is added to the configuration dialog box of the test. When it is clicked, an Erase co
WITE32 Release Notes Version 3.11 The following is the Low Erase Current test configuration dialog box in WITE32 version 3.10: Original band erase
WITE32 Release Notes Version 3.11 The following is an example of the Band Erase dialog box, which opens after you press the Erase Setup… button in
WITE32 Release Notes Version 3.11 2.2 New Adjacent Track Interference Module (WATI) The new Adjacent Track Interference module (WATI module) is
WITE32 Release Notes Version 3.11 2.3.2.1 Dialog Box Layout and Tab Pages The parameters in the Product Parameters dialog box are grouped into th
WITE32 Release Notes Version 3.11 2.3.2.2 Changes of the Disk Type Control The following two changes are introduced in the Disk Type control star
WITE32 Release Notes Version 3.11 2.3.2.3 Head Geometry Parameters The mounting angle of the head suspension on the V2002 cartridge may vary due t
WITE32 Release Notes Version 3.11 2.3.2.4 Micro Actuator Parameters In order to start working with Micro Actuator it has to be enabled and config
WITE32 Release Notes Version 3.11 • The Use CCW Micro Actuator Parameters check box indicates that CCW parameters will be applied to the CW Micr
WITE32 Release Notes Version 3.11 • Changes in the configuration of Guzik Technical Enterprises PCI boards (adding/removing/changing PCI slot) on
WITE32 Release Notes Version 3.11 Table of Contents Chapter 1 New Hardware Supported in WITE32 ...
WITE32 Release Notes Version 3.11 2.6 TAA Calibration Through Programmable Differentiator Starting from WITE32 version 3.11, the calibration of
WITE32 Release Notes Version 3.11 The Errors at The Test End check box If the check box is checked, no error messages during the production test w
WITE32 Release Notes Version 3.11 2.9 Miscellaneous 1. The maximum number of result records in the WITE32 result processor is doubled so that mo
WITE32 Release Notes Version 3.11 9. More descriptive names are used to show the parameters in an operation test configuration dialog box. In WI
WITE32 Release Notes Version 3.11 CHAPTER 3 FIXED BUGS The following bugs were discovered in WITE32 version 3.10 or earlier, and fixed in WITE32
WITE32 Release Notes Version 3.11 12. In WDCP2002, when some spinstand tests are running, an attempt to load or unload Add-Ins from Add-Ins Manag
WITE32 Release Notes Version 3.11 • SR1715 – No readback from the chip registers. Head Amplifier zone/setup dependent parameters are not loaded i
WITE32 Release Notes Version 3.11 3.5 Miscellaneous 1. If V2002 spinstand driver is unchecked during WITE32 installation, the error message “Fail
WITE32 Release Notes Version 3.11 CHAPTER 4 SUPPORT OF MICROSOFT WINDOWS XP OPERATING SYSTEM Microsoft Windows XP Service Pack 1a (SP1a) is supp
WITE32 Release Notes Version 3.11 Guzik Technical Enterprises 29 CHAPTER 5 KNOWN ISSUES For Guzik V2002 spinstand, after upgrading from WI
WITE32 Release Notes Version 3.11 CHAPTER 1 NEW HARDWARE SUPPORTED IN WITE32 1.1 Support of Servo Revision 3 for RWA-2000 Series WITE32 softwar
WITE32 Release Notes Version 3.11 1.4 Micro Actuator Support for Guzik V2002 Spinstands A Micro Actuator is a device located on the suspension of
WITE32 Release Notes Version 3.11 1.5 Head Amplifiers The following head amplifiers are initially supported in WITE32 version 3.11: • 81G214M •
WITE32 Release Notes Version 3.11 CHAPTER 2 WITE32 MODIFICATIONS 2.1 New System Erase and System Band Erase Configuration Two new system confi
WITE32 Release Notes Version 3.11 There are two frames in the dialog box – the Erase Parameters frame and the Band Erase Parameters frame. The Er
WITE32 Release Notes Version 3.11 CAUTION: When you upgrade tos WITE32 version 3.11 from the previous versions of WITE32, the product update proc
WITE32 Release Notes Version 3.11 The following is the SNR test configuration dialog box in WITE32 version 3.10 (provided as an example): Original
Comentários a estes Manuais