7. Error List
Item Code TYPE Error character strings Error Remedy
1 0001 e BAD_SEQUENCE
Communication sequence error
Wait until a response is received before
sending the next command.
2 0002 e INVALID_COMMAND
Invalid (undefined) command. Send a valid command.
3 0004 e INVALID_FORMAT
Invalid command format. Send the command in the valid format.
4 0005 e NOT_POWER_SUPPLIED
The projector's power is off.
Turn on the power using the POWER
ON command.
5 - i BUSY (POWER)
The projector is switching power
modes.
Wait until the power mode is ON, OFF
or PMM.
6 000A e INVALID_PARAMETER
The parameter (type) is invalid
(undefined). Includes cases
when the number of parameters
is incorrect.
Use the correct parameters.
7 000B e JOB_TIMEOUT
Internal processing in the
projector has timed out.
Resend the command.
9 -
i BUSY (NETWORK)
Executing network related
functions.
Wait until the network related functions
have finished execution.
i BUSY (FOCUS)
The focus lens is being driven.
Wait until the projector has finished
driving the focus lens.
i BUSY (ZOOM)
The zoom lens is being driven.
Wait until the projector has finished
driving the zoom lens.
i BUSY (IMAGE)
Image mode switching is in
progress.
Wait until the projector has switched the
image mode.
i BUSY (NOW_SETTING)
Signal setting (detection) in
progress.
Wait until the processing is completed.
i BUSY
Internal processing in the
projector is in progress.
Wait until the current processing is
complete.
10
1006 e NOW_BLANK
Cannot execute command since
blanking operation is in
progress.
Resend the command after canceling
the blanking operation.
1009 e NOW_FREEZE
Cannot execute command since
freeze operation is in progress.
Resend the command after canceling
the freeze operation.
100A e NOW_D.ZOOM
Cannot execute command since
D. zooming is in progress.
Resend the command after canceling
D. zooming.
100B e NOW_SPECIAL_MENU
Cannot execute command in
current menu mode. (Password
display, etc.)
Resend the command after exiting the
current menu mode.
11 F001 e SYSTEM (UNKNOWN)
Internal error has occurred. Resend the command.
12 E0XX e COMMUNICATION_ERROR
A communication protocol
violation has occurred in the
projector.
Resend the command.
1008 e INVALID_SCREEN_ASPECT
Cannot execute command
under current screen aspect
ratio setting.
Change the screen aspect ratio setting.
14 200X e INVALID_SOURCE (****)
Cannot execute command with
current input source.
Change the input source.
15
2010 e NO_SIGNAL
No input signal. Supply the input signal.
201X e INVALID_SIGNAL (****)
Cannot execute command with
current input signal.Current
input signal is indicated in
parentheses.
Change the input signal.