SmartBase MPC600F/MPC400 Chapter 4: Maintenance & Service
[Bit 3]
Select whether to declare the V.8 protocol in DIS signal for reception (mainly caller manual
transmission). If NO is selected, the V.8 protocol cannot be used because it is not declared in DIS
signal.
[Bit 4]
Select whether the receiver falls back during V.34 reception. If OFF is selected, the receiver does
not fall back.
#2 MENU
No. Function Selection range Default setting
08 V.34 max. baud rate 2400
~
3429 3429 (3429 baud)
09 V.34 max. transmission speed 2400
~
33600 33600 (33600 bps)
[No. 08]
Select the maximum baud rate for V.34 transmission: 3429, 3200, 3000, 2800, 2743, and 2400.
This model cannot use 2743 baud due to its modem specificarion. If it is set to 2743 baud,
the maximum baud rate is 2400 baud.
[No.09]
Select the maximum transmission speed for V.34 transmission: 2400 to 33600 bps (2400 × n: 1 n
14).
NOTE