Canon GM-1000 Especificações Página 107

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 140
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 106
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
107
Command ID 161
Command
Name
Counter Clear Timing
Data 0: Head 1
1: Head 2
Return
Value
Timing 0 or 1
Explanation
It is necessary to set the return value as follows.
Head 1 Parameter ID = 11
Head 2 Parameter ID = 14
These values have the standalone motor unique values, and the controller motor set
with servo tuning at Canon has been explained.
When changing the motor or controller, after checking this command Head 1 and Head
2, it is necessary to make settings.
E.g.: A1C101/0 with a return value of 0, set with parameter A1P011/0.
A1C101/1 with a return value of 1, set with parameter A1P014/1.
A2C101/0 with a return value of 1, set with parameter A2P011/1.
A2C101/1 with a return value of 0, set with parameter A2P014/0.
Vista de página 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 139 140

Comentários a estes Manuais

Sem comentários