Canon GM-1000 Especificações Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 140
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
19
2.8. Control Specifications
The controller (GC-201) is operated by:
RS-232C command input
High-speed serial communication
RS-232C
communication command input
High-speed serial communication
Features
- Raster scan and step movement etc.
can be performed easily.
- In order to obtain synchronization
with external equipment, operation
can be started with an external
trigger signal. (Fluctuating delays
may occur within the internal control
sampling time.)
- Vector scans with control over the
desired locations of two axes are
possible. This is used in laser
marking etc.
- Complete synchronization with
external equipment can be obtained
in order to use high-speed serial
communication clock pulses by
controlling the controller.
- As it can be operated with XY2-100
communication specifications, a
controller compliant with XY2-100
can be connected.
Target position
command
RS-232C communication command High-speed serial communication
Operation
setting
parameter
setting
RS-232C communication command RS-232C communication command
Control clock
Uses the controller GC-201 internal
circuit clock pulses
Uses high-speed serial
communication clock pulses
- A target position command input by an RS-232C communication command, or a target position
command from a high-speed serial communication can be mutually switched with a command. (See
2.8.5. “RS-232C Communication Command Input and High-Speed Communication Switching”)