CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
126
9.3. Modifying Parameters
This section explains how to modify parameters.
Control Software
Select the All Parameter tab.
Select an axis for parameter settings.
The current parameter values are displayed.
Modify the parameter values as required. When a parameter value is modified, its cell turns red.
Turn the servo OFF (necessary for modifying parameters).
Press the SET button to reflect modified parameters in the controller settings.
Turn the servo ON.
Note: Pressing the SET button reflects modified parameters in the controller settings but does not write
them into the controller ROM. When the power is turned off and on again, the controller starts with the old
parameters read from ROM. See 9.4 for writing modified parameters into ROM.