CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
20
- With the default settings at shipping, power-on starts up the controller with in RS-232 Communication
Command Input mode.
- The parameter can be set to determine which mode the controller starts after power-on. (See 6.1.
“Setting Controller Start Up Mode”)
Note:
For start up when set to the High-Speed Serial Communication mode, in order to use high-speed
serial communication clock pulses internally, signal input by high-speed serial communication is
necessary at power-on. When there is no signal input, a Clock Lack error occurs. (See 10.2. “Errors”)
After an error occurs, and input of a high-speed serial communication signal begins correctly,
operation begins automatically from the high-speed serial communication signal.